DC Field | Value | Language |
dc.contributor.author | Chepurnov, A. S. | - |
dc.contributor.author | Ionidi, V. Y. | - |
dc.contributor.author | Ivashchuk, O. O. | - |
dc.contributor.author | Kubankin, A. S. | - |
dc.contributor.author | Oleinik, A. N. | - |
dc.contributor.author | Shchagin, A. V. | - |
dc.date.accessioned | 2021-01-15T12:27:19Z | - |
dc.date.available | 2021-01-15T12:27:19Z | - |
dc.date.issued | 2016 | - |
dc.identifier.citation | Pyroelectric neutron generator for calibration of neutrino and dark matter detectors / A.S. Chepurnov [et al.] // Journal of Physics: Conference Series. - 2016. - Vol.675, №3. - Art.32031. - URL: https://iopscience.iop.org/article/10.1088/1742-6596/675/3/032031. | - |
dc.identifier.uri | http://dspace.bsu.edu.ru/handle/123456789/36924 | - |
dc.description.abstract | Pyroelectric crystals, such as LiNbO3 or LiTaO3 being under influence of a temperature gradient can produce an electric field up to 105 kV/cm. Due to such properties as On/Off mode of operation and the absence of radioactive materials, pyroelectric neutron generators seem to be a promising tool for calibration of neutrino and dark matter and other low background detectors. We propose the application of the controlled pyroelectric neutron generator for calibration of such detectors | - |
dc.language.iso | en | - |
dc.rights | 2-s2.0-84964744510 | - |
dc.subject | pyroelectric neutron generatorh | - |
dc.subject | neutrino | - |
dc.subject | dark matter | - |
dc.subject | detectors | - |
dc.title | Pyroelectric neutron generator for calibration of neutrino and dark matter detectors | - |
dc.type | Conference Paper | - |
dc.identifier.citationpublication | Journal of Physics: Conference Series | - |
dc.identifier.citationnumber | 3 | - |
dc.identifier.citationvolume | 675 | - |
Appears in Collections: | Статьи из периодических изданий и сборников (на иностранных языках) = Articles from periodicals and collections (in foreign languages)
|